{"product_id":"insulation-anchor-with-plastic-nail-10x200mm-60mm-plate-short-expansion-zone","title":"Insulation Anchor with Plastic Nail 10x200mm (60mm Plate, Short Expansion Zone)","description":"\u003cp\u003eQuick installation and reliable fixation – ideally suited for effective thermal insulation reinforcement.\u003c\/p\u003e\n\u003cp\u003eLIN insulation anchor 10 × 180 mm with a short expansion zone and fiberglass reinforced polyamide nail is designed for simple and quick mechanical installation of insulation materials, especially when the substrate material is not very dense or when it is necessary to reduce the drilling depth. This anchor provides high durability while maintaining a straightforward installation process.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShort expansion zone – reduces the required drilling depth, allowing installation in thinner structures\u003c\/li\u003e\n\u003cli\u003eFiberglass reinforced polyamide nail – lightweight yet resistant to pull-out and breakage\u003c\/li\u003e\n\u003cli\u003e60 mm pressure plate – uniform load distribution on the insulation material\u003c\/li\u003e\n\u003cli\u003eNon-metallic construction – prevents thermal bridges, ideally suited for ETICS systems\u003c\/li\u003e\n\u003cli\u003eETA certification – complies with European technical requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eTechnical Information:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDrill diameter: 10 mm\u003c\/li\u003e\n\u003cli\u003eDrill depth: ≥ 60 mm\u003c\/li\u003e\n\u003cli\u003eEffective anchoring depth: ≥ 50 mm\u003c\/li\u003e\n\u003cli\u003ePressure plate diameter: 60 mm\u003c\/li\u003e\n\u003cli\u003eAnchor material: polypropylene (PP)\u003c\/li\u003e\n\u003cli\u003eNail material: fiberglass reinforced polyamide\u003c\/li\u003e\n\u003cli\u003eCertification: ETA (European Technical Assessment)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\"\u003eACCEPTED SUBSTRATE\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eDENSITY [kg\/dm³]\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eMINIMUM PRESSURE [N\/mm²]\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eAPPLICABLE STANDARD\u003c\/th\u003e\n\u003cth style=\"text-align: center;\"\u003eCharacteristic Resistance NRk [kN]\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcrete C12\/15 (application category A)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 206\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcrete C16\/20 to C50\/60 (application category A)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 206\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeramic solid bricks MZ (application category B)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥2.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥20.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 771-1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium silicate bricks KS (application category B)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥2.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥20.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 771-2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertically perforated ceramic bricks Porotherm 25 P+D (category C)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥0.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥15.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 771-1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHollow calcium silicate blocks KSL (application category C)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥1.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥15.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 771-2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLightweight concrete blocks LAC (application category D)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥0.88\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e≥5.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEN 771-3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePartial safety factor for anchor resistance ɣM (1)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eInstallation:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"10\" cellspacing=\"0\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/mk-plugs.com\/wp-content\/uploads\/2023\/06\/lipn-1.png\" alt=\"1. step\" width=\"150\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/mk-plugs.com\/wp-content\/uploads\/2023\/06\/lipn-2.png\" alt=\"2. step\" width=\"150\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/mk-plugs.com\/wp-content\/uploads\/2023\/06\/lipn-3.png\" alt=\"3. step\" width=\"150\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/mk-plugs.com\/wp-content\/uploads\/2023\/06\/lipn-4.png\" alt=\"4. step\" width=\"150\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1) Drill the wall\u003c\/td\u003e\n\u003ctd\u003e2) Insert the anchor into the hole\u003c\/td\u003e\n\u003ctd\u003e3) Secure the anchor by inserting the plugs\u003c\/td\u003e\n\u003ctd\u003e4) Properly installed insulation connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cimg id=\"el-image-1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0923\/0997\/9481\/files\/lv-import-scheme1.png?v=1759230754\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum substrate thickness — \u003cb\u003eh\u003c\/b\u003e [mm]\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum connector distance — \u003cb\u003eSmin\u003c\/b\u003e [mm]\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum distance between anchor and substrate - \u003cb\u003eCmin\u003c\/b\u003e [mm]\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cimg id=\"el-image-111\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0923\/0997\/9481\/files\/lv-import-scheme-2.png?v=1759230755\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"10\" cellspacing=\"0\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSuitable for:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecuring mineral wool, foam, and other insulation materials\u003c\/li\u003e\n\u003cli\u003eETICS (external thermal insulation composite systems)\u003c\/li\u003e\n\u003cli\u003eConstruction work with limited drilling depth\u003c\/li\u003e\n\u003cli\u003eNew construction and renovation projects\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"4PRO","offers":[{"title":"Default Title","offer_id":56272543809881,"sku":"LIN10200","price":0.0,"currency_code":"PLN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0923\/0997\/9481\/files\/siltumizolacijas-dibelis-ar-plastmasas-naglu.png?v=1773153381","url":"https:\/\/ott-polski.manta.link\/en\/products\/insulation-anchor-with-plastic-nail-10x200mm-60mm-plate-short-expansion-zone","provider":"Ottensten","version":"1.0","type":"link"}